sysklogd/man/syslogd.8

481 lines
11 KiB
Groff
Raw Normal View History

.\" Copyright (c) 1983, 1986, 1991, 1993
.\" The Regents of the University of California. All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\" notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\" notice, this list of conditions and the following disclaimer in the
.\" documentation and/or other materials provided with the distribution.
.\" 3. Neither the name of the University nor the names of its contributors
.\" may be used to endorse or promote products derived from this software
.\" without specific prior written permission.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" @(#)syslogd.8 8.1 (Berkeley) 6/6/93
.\" $FreeBSD$
.\"
.Dd July 2, 2018
.Dt SYSLOGD 8
.Os
.Sh NAME
.Nm syslogd
.Nd log systems messages
.Sh SYNOPSIS
.Nm
.Op Fl 468ACcdFHkNnosTuv
.Op Fl a Ar allowed_peer
.Op Fl b Ar bind_address
.Op Fl f Ar config_file
.Op Fl l Oo Ar mode Ns \&: Oc Ns Ar path
.Op Fl m Ar mark_interval
.Op Fl O Ar format
.Op Fl P Ar pid_file
.Op Fl p Ar log_socket
.Op Fl S Ar logpriv_socket
.Sh DESCRIPTION
The
.Nm
utility reads and logs messages to the system console,
log files,
other
machines and/or users as specified by its configuration file.
.Pp
The options are as follows:
.Bl -tag -width indent
.It Fl 4
Force
.Nm
to use IPv4 addresses only.
.It Fl 6
Force
.Nm
to use IPv6 addresses only.
.It Fl 8
Tells
.Nm
not to interfere with 8-bit data.
Normally
.Nm
will replace C1 control characters
.Pq ISO 8859 and Unicode characters
with their
.Dq M- Ns Em x
equivalent.
Note, this option does not change the way
.Nm
alters control characters
.Pq see Xr iscntrl 3 .
They will always be replaced with their
.Dq ^ Ns Em x
equivalent.
.It Fl A
Ordinarily,
.Nm
tries to send the message to only one address
even if the host has more than one A or AAAA record.
If this option is specified,
.Nm
tries to send the message to all addresses.
.It Fl a Ar allowed_peer
Allow
.Ar allowed_peer
to log to this
.Nm
using UDP datagrams.
Multiple
.Fl a
options may be specified.
.Pp
The
.Ar allowed_peer
option may be any of the following:
.Bl -tag -width "ipaddr[/prefixlen][:service]XX"
.It Xo
.Sm off
.Ar ipaddr
.Op / Ar masklen
.Op \&: Ar service
.Pp
.Ar ipaddr
.Op / Ar prefixlen
.Op \&: Ar service
.Sm on
.Xc
Accept datagrams from
.Ar ipaddr ,
.Ar ipaddr
can be specified as an IPv4 address or as an IPv6
address enclosed with
.Ql \&[
and
.Ql \&] .
If specified,
.Ar service
is the name or number of an UDP service (see
.Xr services 5 )
the source packet must belong to.
A
.Ar service
of
.Ql \&*
accepts UDP packets from any source port.
The default
.Ar service
is
.Ql syslog .
If
.Ar ipaddr
is IPv4 address, a missing
.Ar masklen
will be substituted by the historic class A or class B netmasks if
.Ar ipaddr
belongs into the address range of class A or B,
respectively,
or by 24 otherwise.
If
.Ar ipaddr
is IPv6 address,
a missing
.Ar masklen
will be substituted by 128.
.It Xo
.Sm off
.Ar domainname Op \&: Ar service
.Sm on
.Xc
Accept datagrams where the reverse address lookup yields
.Ar domainname
for the sender address.
The meaning of
.Ar service
is as explained above.
.Ar domainname
can contain special characters of a shell-style pattern such as
.Ql Li \&* .
.El
.Pp
The
.Fl a
options are ignored if the
.Fl s
option is also specified.
.It Xo
.Fl b
.Sm off
.Ar bind_address Op \&: Ar service
.Sm on
.Xc
.It Xo
.Fl b
.Sm off
.Li \&: Ar service
.Sm on
.Xc
Bind to a specific address and/or port.
The address can be specified as a hostname,
and the port as a service name.
If an IPv6 address is specified, it should be enclosed with
.Ql \&[
and
.Ql \&] .
The default
.Ar service
is
.Ql syslog .
This option can be specified multiple times to bind to
multiple addresses and/or ports.
.It Fl C
Create log files that do not exist
.Pq permission is set to Ql Li 0600 .
.It Fl c
Disable the compression of repeated instances of the same line
into a single line of the form
.Dq Li "last message repeated N times"
when the output is a pipe to another program.
If specified twice,
disable this compression in all cases.
.It Fl d
Put
.Nm
into debugging mode.
This is probably only of use to developers working on
.Nm .
.It Fl f Ar config_file
Specify the pathname of an alternate configuration file;
the default is
.Pa /etc/syslog.conf .
.It Fl F
Run
.Nm
in the foreground,
rather than going into daemon mode.
This is useful if some other process uses
.Xr fork 2
and
.Xr exec 3
to run
.Nm ,
and wants to monitor when and how it exits.
.It Fl H
When logging remote messages use hostname from the message (if supplied)
instead of using address from which the message was received.
.It Fl k
Disable the translation of
messages received with facility
.Dq kern
to facility
.Dq user .
Usually the
.Dq kern
facility is reserved for messages read directly from
.Pa /dev/klog .
.It Fl m Ar mark_interval
Select the number of minutes between
.Dq mark
messages;
the default is 20 minutes.
.It Fl N
Disable binding on UDP sockets.
RFC 3164 recommends that outgoing
.Nm
messages should originate from the privileged port,
this option
.Em disables
the recommended behavior.
This option inherits
.Fl s .
.It Fl n
Disable DNS query for every request.
.It Fl O Ar format
Select the output format of generated log messages.
The values
.Ar bsd
and
.Ar rfc3164
are used to generate RFC 3164 log messages.
The values
.Ar syslog
and
.Ar rfc5424
are used to generate RFC 5424 log messages,
having RFC 3339 timestamps with microsecond precision.
The default is to generate RFC 3164 log messages.
.It Fl o
Prefix kernel messages with the full kernel boot file as determined by
.Xr getbootfile 3 .
Without this, the kernel message prefix is always
.Dq Li kernel: .
.It Fl p Ar log_socket
Specify the pathname of an alternate log socket to be used instead;
the default is
.Pa /var/run/log .
When a single
.Fl p
option is specified,
the default pathname is replaced with the specified one.
When two or more
.Fl p
options are specified,
the remaining pathnames are treated as additional log sockets.
.It Fl P Ar pid_file
Specify an alternative file in which to store the process ID.
The default is
.Pa /var/run/syslog.pid .
.It Fl S Ar logpriv_socket
Specify the pathname of an alternate log socket for privileged
applications to be used instead;
the default is
.Pa /var/run/logpriv .
When a single
.Fl S
option is specified,
the default pathname is replaced with the specified one.
When two or more
.Fl S
options are specified,
the remaining pathnames are treated as additional log sockets.
.It Fl l Oo Ar mode Ns \&: Oc Ns Ar path
Specify a location where
.Nm
should place an additional log socket.
The primary use for this is to place additional log sockets in
.Pa /var/run/log
of various chroot filespaces.
File permissions for socket can be specified in octal representation in
.Ar mode ,
delimited with a colon.
The socket location must be specified as an absolute pathname in
.Ar path .
.It Fl s
Operate in secure mode.
Do not log messages from remote machines.
If specified twice,
no network socket will be opened at all,
which also disables logging to remote machines.
.It Fl T
Always use the local time and date for messages received from the network,
instead of the timestamp field supplied in the message by the remote host.
This is useful if some of the originating hosts cannot keep time properly
or are unable to generate a correct timestamp.
.It Fl u
Unique priority logging.
Only log messages at the specified priority.
Without this option,
messages at the stated priority or higher are logged.
This option changes the default comparison from
.Dq =>
to
.Dq = .
.It Fl v
Verbose logging.
If specified once,
the numeric facility and priority are
logged with each locally-written message.
If specified more than once,
the names of the facility and priority are logged with each locally-written
message.
.Pp
This option only affects the formatting of RFC 3164 messages.
Messages formatted according to RFC 5424 always include a
facility/priority number.
.El
.Pp
The
.Nm
utility reads its configuration file when it starts up and whenever it
receives a hangup signal.
For information on the format of the configuration file,
see
.Xr syslog.conf 5 .
.Pp
The
.Nm
utility reads messages from the
.Ux
domain sockets
.Pa /var/run/log
and
.Pa /var/run/logpriv ,
from an Internet domain socket specified in
.Pa /etc/services ,
and from the special device
.Pa /dev/klog
.Pq to read kernel messages .
.Pp
The
.Nm
utility creates its process ID file,
by default
.Pa /var/run/syslog.pid ,
and stores its process
ID there.
This can be used to kill or reconfigure
.Nm .
.Pp
The message sent to
.Nm
should consist of a single line.
The message can contain a priority code,
which should be a preceding
decimal number in angle braces,
for example,
.Sq Aq 5 .
This priority code should map into the priorities defined in the
include file
.In sys/syslog.h .
.Pp
For security reasons,
.Nm
will not append to log files that do not exist
.Po unless Fl C
option is specified
.Pc ;
therefore, they must be created manually before running
.Nm .
.Pp
The date and time are taken from the received message.
If the format of the timestamp field is incorrect,
time obtained from the local host is used instead.
This can be overridden by the
.Fl T
flag.
.Sh FILES
.Bl -tag -width /var/run/syslog.pid -compact
.It Pa /etc/syslog.conf
configuration file
.It Pa /var/run/syslog.pid
default process ID file
.It Pa /var/run/log
name of the
.Ux
domain datagram log socket
.It Pa /var/run/logpriv
.Ux
socket for privileged applications
.It Pa /dev/klog
kernel log device
.El
.Sh SEE ALSO
.Xr logger 1 ,
.Xr syslog 3 ,
.Xr services 5 ,
.Xr syslog.conf 5 ,
.Xr newsyslog 8
.Sh HISTORY
The
.Nm
utility appeared in
.Bx 4.3 .
.Pp
The
.Fl a ,
.Fl s ,
.Fl u ,
and
.Fl v
options are
.Fx 2.2
extensions.
.Sh BUGS
The ability to log messages received in UDP packets is equivalent to
an unauthenticated remote disk-filling service,
and should probably be disabled by default.
Some sort of
.No inter- Ns Nm syslogd
authentication mechanism ought to be worked out.
To prevent the worst abuse,
use of the
.Fl a
option is therefore highly recommended.
.Pp
The
.Fl a
matching algorithm does not pretend to be very efficient;
use of numeric IP addresses is faster than domain name comparison.
Since the allowed peer list is being walked linearly,
peer groups where frequent messages are being anticipated
from should be put early into the
.Fl a
list.
.Pp
The log socket was moved from
.Pa /dev
to ease the use of a read-only root file system.
This may confuse
some old binaries so that a symbolic link might be used for a
transitional period.